Description
- Take 2 BOD measurements at a time
- Wireless electrodes available—take measurements anywhere in your lab
- Compatible with both digital optical BOD probes and YSI 5010 BOD probes
Streamline your lab with these flexible multiparameter meters. They measure DO/BOD, pH, ORP and conductivity using intelligent digital sensor (IDS) technology that lets them communicate with probes—including probe ID, parameter measured and calibration data.
All meters feature AutoStable function, which constantly evaluates your measurement's stability to ensure reproducible results. When measuring pH, a bar graph indicates if you're measuring in the optimal pH range for your calibration values. Save data sets manually or automatically based on user-defined time intervals. When saving automatically, a graph on the display shows your progress. Transfer data to Excel® through USB connection for further analysis.
Two-channel meters feature a large color graphic display that shows readings for either all channels at once or one channel at a time. They calculate oxygen uptake rate (OUR) and specific oxygen uptake rate (SOUR) to simplify compliance with EPA 503 regulations and provide useful tools for plant optimization. Store up to 500 data sets manually or 10,000 in automatic mode.
Many probe/electrode and adapter options available
IDS probes are galvanically isolated digital probes that store their own calibration history and serial number. Measurements are processed and transferred digitally, which compensates for variable cable lengths and eliminates signal interference. pH electrodes with built-in ATC take fast, accurate measurements. IDS wireless pH, ORP or conductivity electrodes send measurements to your meter via Bluetooth® from as far as 10 meters away—take measurements anywhere in your lab while the meter stays in its safe, dry space.
Optional adapters allow for even more customization.
The 4011 adapter lets you use the MultiLab meter with the YSI 5010 stirring BOD probe. The stirrer adapter (for use with 2- and 3-channel meters only) lets you power up to three BOD stirrers to take up to three BOD measurements at once. Digital to BNC adapter (for use with 2- and 3-channel meters only) lets you take measurements using your favorite non-digital BNC-compatible ISE or pH electrodes.
Meters include: universal power supply, electrode stand, manual, software and USB cable. 3-year meter warranty.
- pH
Range: 0.000 to 14.000 pH
Resolution: 0.001 pH
Accuracy: ±0.004 pH - mV
Range: -1200 to +1200 mV
Resolution: 1 mV - Concentration
Range: 0 to 999,999 (depends on ISE probe used)
Resolution: up to 0.001
Units: mg/L - Dissolved oxygen
Range: 0 to 50 mg/L; 0 to 500% air saturation
Resolution: 0.01 mg/L; 0.1%
Accuracy: ±0.1 mg/L or ±1% of reading (0 to 20 mg/L); ±10 mg/L or ±10% of reading (20 to 50 mg/L) - Conductivity
Range: 0 to 2000 mS/cm (auto ranging)
Resolution: 0.01, 0.1, 1 µS; 0.01, 0.1, 1 mS
Accuracy: ±0.5% of value - Resistivity
Range: 0 to 100 MO (auto ranging)
Resolution: 0.1/1 O, kO and MO
Accuracy: ±0.5% of value - TDS
Range: 0 to 1999 mg/L; 0.0 to 199.9 g/L (auto ranging)
Resolution: 1; 0.1 mg/L
Accuracy: ±0.5% of value - Salinity
Range: 0.0 to 70.0 ppt
Resolution: 0.1 ppt
Accuracy: ±0.5% of value - Temperature
Range: 0 to 100°C (32 to 212°F)
Resolution: 0.1°
Accuracy: ±0.2°C or F - Calibration points: up to 7
Product Information
- Item number
- 87769
- Brand Name
- YSI
- Catalog Page
- 719
- Net weight
- 14.4
- Condition
- New
Accessories
Related
YSI MultiLab Multiparameter Meter, DO/BOD/pH/ORP/Cond, 2-Channel, 4010-2W
- Item number
- 87769
- Brand Name
- YSI
- Catalog Page
- 719
- Net weight
- 14.4
- Condition
- New
- Take 2 BOD measurements at a time
- Wireless electrodes available—take measurements anywhere in your lab
- Compatible with both digital optical BOD probes and YSI 5010 BOD probes
Streamline your lab with these flexible multiparameter meters. They measure DO/BOD, pH, ORP and conductivity using intelligent digital sensor (IDS) technology that lets them communicate with probes—including probe ID, parameter measured and calibration data.
All meters feature AutoStable function, which constantly evaluates your measurement's stability to ensure reproducible results. When measuring pH, a bar graph indicates if you're measuring in the optimal pH range for your calibration values. Save data sets manually or automatically based on user-defined time intervals. When saving automatically, a graph on the display shows your progress. Transfer data to Excel® through USB connection for further analysis.
Two-channel meters feature a large color graphic display that shows readings for either all channels at once or one channel at a time. They calculate oxygen uptake rate (OUR) and specific oxygen uptake rate (SOUR) to simplify compliance with EPA 503 regulations and provide useful tools for plant optimization. Store up to 500 data sets manually or 10,000 in automatic mode.
Many probe/electrode and adapter options available
IDS probes are galvanically isolated digital probes that store their own calibration history and serial number. Measurements are processed and transferred digitally, which compensates for variable cable lengths and eliminates signal interference. pH electrodes with built-in ATC take fast, accurate measurements. IDS wireless pH, ORP or conductivity electrodes send measurements to your meter via Bluetooth® from as far as 10 meters away—take measurements anywhere in your lab while the meter stays in its safe, dry space.
Optional adapters allow for even more customization.
The 4011 adapter lets you use the MultiLab meter with the YSI 5010 stirring BOD probe. The stirrer adapter (for use with 2- and 3-channel meters only) lets you power up to three BOD stirrers to take up to three BOD measurements at once. Digital to BNC adapter (for use with 2- and 3-channel meters only) lets you take measurements using your favorite non-digital BNC-compatible ISE or pH electrodes.
Meters include: universal power supply, electrode stand, manual, software and USB cable. 3-year meter warranty.
- pH
Range: 0.000 to 14.000 pH
Resolution: 0.001 pH
Accuracy: ±0.004 pH - mV
Range: -1200 to +1200 mV
Resolution: 1 mV - Concentration
Range: 0 to 999,999 (depends on ISE probe used)
Resolution: up to 0.001
Units: mg/L - Dissolved oxygen
Range: 0 to 50 mg/L; 0 to 500% air saturation
Resolution: 0.01 mg/L; 0.1%
Accuracy: ±0.1 mg/L or ±1% of reading (0 to 20 mg/L); ±10 mg/L or ±10% of reading (20 to 50 mg/L) - Conductivity
Range: 0 to 2000 mS/cm (auto ranging)
Resolution: 0.01, 0.1, 1 µS; 0.01, 0.1, 1 mS
Accuracy: ±0.5% of value - Resistivity
Range: 0 to 100 MO (auto ranging)
Resolution: 0.1/1 O, kO and MO
Accuracy: ±0.5% of value - TDS
Range: 0 to 1999 mg/L; 0.0 to 199.9 g/L (auto ranging)
Resolution: 1; 0.1 mg/L
Accuracy: ±0.5% of value - Salinity
Range: 0.0 to 70.0 ppt
Resolution: 0.1 ppt
Accuracy: ±0.5% of value - Temperature
Range: 0 to 100°C (32 to 212°F)
Resolution: 0.1°