Hach SubAV Oil-filled Flow Sensor (with FL1500 Bare WIre), 30-ft Range, 30'L Cable, 77274-030

Item No.84778
Product Details Accurately read flow in open channels and partially filled pipes Designed to resist fouling in wastewater and stormwater installations For use with Hach FL1500 flow meters, FL900 battery-powered loggers and AS950 samplers Accurately measure flow rates in open channels and partially f
Price $2210.13
price per each
excl. tax
Call for availability

Description

Product Details
  • Accurately read flow in open channels and partially filled pipes
  • Designed to resist fouling in wastewater and stormwater installations
  • For use with Hach FL1500 flow meters, FL900 battery-powered loggers and AS950 samplers

Accurately measure flow rates in open channels and partially filled pipes with the Hach Submerged Area Velocity Sensor (SubAV). Its 2-in-1 design pairs an acoustic doppler flow sensor with a pressure transducer to calculate flow. Rugged and reliable, it automatically corrects for swings in water temperature and salinity concentration to produce precise flow data at any site—whether at your plant or a remote location.

Sensors mount in the bottom of partially filled open channel systems (with consideration for silt buildup) and should be covered by at least 0.8" of liquid at all times. Optional installation band accessories let you mount sensors in pipe openings. These oil-filled sensors are ideal where high levels of biological growth, grit or silt could foul the integral pressure transducer.

The SubAV sensor is for use with Hach's FL1500 meters, FL900 loggers and select AS950 samplers. It communicates flow data to these devices via the AV9000 analyzer module (sold separately, or available pre-installed on select meters and loggers). The AV9000 features advanced signal processing and filtering options that let you use your sensor in difficult applications that call for better resolution. For peace of mind, the AV9000's advanced diagnostics let you verify that your sensor is working properly before you leave the site.

Includes: sensor with 30'L cable, bare wire terminating ends (for conduit routing). For a complete system, order a SubAV sensor, desiccant hub assembly, junction box, hub cable, potting kit, potting dispensing gun, flow meter/logger/sampler, compatible AV9000 analyzer module, and pipe installation accessories as needed per application.

Tech Specs:
  • Range: velocity, -5 to 20 ft/s; level, 0 to 30 ft
  • Materials: Noryl® shell, epoxy potting, stainless steel, urethane cable
  • Voltage: supplied by compatible instrument module
  • Compatibility: via Hach AV9000 module installed in FL1500 flow meters, FL900 loggers, AS950 samplers
  • Dimensions: 1.5"W x 0.9"H x 5.31"D

Product Information

Item number
84778
Brand Name
Hach Company
Catalog Page
438
Net weight
3.307
Condition
New

Hach SubAV Oil-filled Flow Sensor (with FL1500 Bare WIre), 30-ft Range, 30'L Cable, 77274-030

Item number
84778
Brand Name
Hach Company
Catalog Page
438
Net weight
3.307
Condition
New
Price $2210.13
price per each
excl. tax
Call for availability
each
Need Help? Call 800-548-1234
Product Details
  • Accurately read flow in open channels and partially filled pipes
  • Designed to resist fouling in wastewater and stormwater installations
  • For use with Hach FL1500 flow meters, FL900 battery-powered loggers and AS950 samplers

Accurately measure flow rates in open channels and partially filled pipes with the Hach Submerged Area Velocity Sensor (SubAV). Its 2-in-1 design pairs an acoustic doppler flow sensor with a pressure transducer to calculate flow. Rugged and reliable, it automatically corrects for swings in water temperature and salinity concentration to produce precise flow data at any site—whether at your plant or a remote location.

Sensors mount in the bottom of partially filled open channel systems (with consideration for silt buildup) and should be covered by at least 0.8" of liquid at all times. Optional installation band accessories let you mount sensors in pipe openings. These oil-filled sensors are ideal where high levels of biological growth, grit or silt could foul the integral pressure transducer.

The SubAV sensor is for use with Hach's FL1500 meters, FL900 loggers and select AS950 samplers. It communicates flow data to these devices via the AV9000 analyzer module (sold separately, or available pre-installed on select meters and loggers). The AV9000 features advanced signal processing and filtering options that let you use your sensor in difficult applications that call for better resolution. For peace of mind, the AV9000's advanced diagnostics let you verify that your sensor is working properly before you leave the site.

Includes: sensor with 30'L cable, bare wire terminating ends (for conduit routing). For a complete system, order a SubAV sensor, desiccant hub assembly, junction box, hub cable, potting kit, potting dispensing gun, flow meter/logger/sampler, compatible AV9000 analyzer module, and pipe installation accessories as needed per application.

Tech Specs:
  • Range: velocity, -5 to 20 ft/s; level, 0 to 30 ft
  • Materials: Noryl® shell, epoxy potting, stainless steel, urethane cable
  • Voltage: supplied by compatible instrument module
  • Compatibility: via Hach AV9000 module installed in FL1500 flow meters, FL900 loggers, AS950 samplers
  • Dimensions: 1.5"W x 0.9"H x 5.31"D