Product Details
  • Simple 4-20mA loop-powered wiring
  • High-contrast LCD display shows level in feet and inches plus tank level bar graph
  • Rugged NEMA 4X enclosure with rotatable backlit display is viewable at 80° arc

Vantageview PD6701 meters feature an easy-to-read 0.6"-high display that clearly shows level in feet and inches, with readout to eighths or sixteenths of an inch. The 20-segment tank level bar graph provides a clear indicator of height at a glance, and is independently scaleable to indicate empty to full status. Lower display can show scaleable volume, percent full, or a custom tag of your own with up to seven alphanumeric characters.

The Vantageview accepts an analog input signal, making it a great choice for nearly any level or pressure sensor with 4-20 mA output. It also features an open collector output, programmable for high or low alarms, with corresponding alert indicators on the display. Wire the included digital input to an external switch as a reset to clear alarm.

Vantageview PD6701 display meters are ideal for wet, dirty environments. The large backlit display offers a wide viewing arc of 80°, nearly twice that of competitive models. It rotates 0°, 90°, 180° or 270°, making mounting easy. Four SafeTouch® sensors operate as through-window buttons— program and operate your meter without removing the cover (and exposing the electronics). These buttons can also be disabled for security. Additional mechanical buttons are located under the viewing cover as well.

Password protection keeps unwanted programming changes from occurring. Its rugged NEMA 4X enclosure features three conduit openings, and can be flat surface mounted using the integral flanges, or pipe mounted with a kit (sold separately).

The PD6701 Vantageview features live input scaling, which can be used in lieu of standard 4-20 mA value input scaling. It's performed with a precision signal source at any two points along the scale, and allows an operator to set a "best fit straight line" for nonlinear input spans. A programmable 32-point linearization function allows readout of odd-shaped tanks such as conical tanks.

Vantageview models designed for flowmeter rate and totalizing are also available.

Tech Specs:
  • Display: upper: feet & inches display, 0.6"H, 0 to 399 ft with 1/16 or 1/8 fractional display; lower: 0.4"H, 7-character alphanumeric display tank level indicator (bargraph): 20 segments, F (full) and E (empty)
  • Input: 4-20 mA
  • Power: 9-30 VDC loop power with input; backlight power with loop or external 9-36 VDC
  • Output: 1: open collector 30 VDC at 150 mA max (configure as high or low alarm)
  • Digital input: 1, for external alarm reset

Product Information

Item number
13362
Brand Name
Precision Digital Corporation
Net weight
2.4
Condition
New

Precision Digital Vantageview PD6701 Level Display Meter w/ 4-20 mA Input, 9-30 VDC Loop Powered

Item number
13362
Brand Name
Precision Digital Corporation
Net weight
2.4
Condition
New
Price $727.65
price per each
excl. tax
Call for availability
each
Need Help? Call 800-548-1234
Product Details
  • Simple 4-20mA loop-powered wiring
  • High-contrast LCD display shows level in feet and inches plus tank level bar graph
  • Rugged NEMA 4X enclosure with rotatable backlit display is viewable at 80° arc

Vantageview PD6701 meters feature an easy-to-read 0.6"-high display that clearly shows level in feet and inches, with readout to eighths or sixteenths of an inch. The 20-segment tank level bar graph provides a clear indicator of height at a glance, and is independently scaleable to indicate empty to full status. Lower display can show scaleable volume, percent full, or a custom tag of your own with up to seven alphanumeric characters.

The Vantageview accepts an analog input signal, making it a great choice for nearly any level or pressure sensor with 4-20 mA output. It also features an open collector output, programmable for high or low alarms, with corresponding alert indicators on the display. Wire the included digital input to an external switch as a reset to clear alarm.

Vantageview PD6701 display meters are ideal for wet, dirty environments. The large backlit display offers a wide viewing arc of 80°, nearly twice that of competitive models. It rotates 0°, 90°, 180° or 270°, making mounting easy. Four SafeTouch® sensors operate as through-window buttons— program and operate your meter without removing the cover (and exposing the electronics). These buttons can also be disabled for security. Additional mechanical buttons are located under the viewing cover as well.

Password protection keeps unwanted programming changes from occurring. Its rugged NEMA 4X enclosure features three conduit openings, and can be flat surface mounted using the integral flanges, or pipe mounted with a kit (sold separately).

The PD6701 Vantageview features live input scaling, which can be used in lieu of standard 4-20 mA value input scaling. It's performed with a precision signal source at any two points along the scale, and allows an operator to set a "best fit straight line" for nonlinear input spans. A programmable 32-point linearization function allows readout of odd-shaped tanks such as conical tanks.

Vantageview models designed for flowmeter rate and totalizing are also available.

Tech Specs:
  • Display: upper: feet & inches display, 0.6"H, 0 to 399 ft with 1/16 or 1/8 fractional display; lower: 0.4"H, 7-character alphanumeric display tank level indicator (bargraph): 20 segments, F (full) and E (empty)
  • Input: 4-20 mA
  • Power: 9-30 VDC loop power with input; backlight power with loop or external 9-36 VDC
  • Output: 1: open collector 30 VDC at 150 mA max (configure as high or low alarm)
  • Digital input: 1, for external alarm reset