Hach GLI Impeller Flow Sensor Tee Mount (Reg. Mounting T), Polypropylene Body, 20 ft Cable, F1A11A1T
Description
- Tee-mount, pipe thread and hot-tap versions
- Measure flow in pipe sizes from 1/2 to 100"
GLI insertion-type impeller flow sensors are excellent for measuring flow in wells, process control, effluent, irrigation and many other flow metering applications. Sensors are constructed of durable materials for long life and use a non-magnetic sensing system that does not create drag on the efficient 6-bladed impeller—providing good performance at low velocities. The GLI flow sensors can be mounted up to 2,000 feet away from the flow analyzer/display unit. Choose from the tee-mounted (socket) version for smaller pipe sizes or the adjustable pipe-thread mounted versions for use in pipes from 2 to 100".
Note: Hot-tap sensors do not include ball valve. Tee-mount sensors require GLI mounting hardware listed below
- Measuring range: 1 to 30 ft/sec
- Accuracy: ±1% of full scale from 1 to 30 ft/sec
- Repeatability: plus or minus 0.5% of full scale
- Linearity: plus or minus 1% of full scale
- Max pressure: 100 psi @ 77°F
- Max temp: 140°F @ 40 psi
- Mounting hardware: Sch 80 PVC
- Sensor cable: 20-ft, 2-conductor plus shield, extend to 2,000 ft
- Construction: polypropylene body & impeller, zirconia ceramic shaft
- Sensor type: tee mount
Product Information
- Item number
- 40287
- Brand Name
- Hach Company
- Catalog Page
- 412
- Net weight
- 1.4
- Condition
- New
Hach GLI Impeller Flow Sensor Tee Mount (Reg. Mounting T), Polypropylene Body, 20 ft Cable, F1A11A1T
- Item number
- 40287
- Brand Name
- Hach Company
- Catalog Page
- 412
- Net weight
- 1.4
- Condition
- New
- Tee-mount, pipe thread and hot-tap versions
- Measure flow in pipe sizes from 1/2 to 100"
GLI insertion-type impeller flow sensors are excellent for measuring flow in wells, process control, effluent, irrigation and many other flow metering applications. Sensors are constructed of durable materials for long life and use a non-magnetic sensing system that does not create drag on the efficient 6-bladed impeller—providing good performance at low velocities. The GLI flow sensors can be mounted up to 2,000 feet away from the flow analyzer/display unit. Choose from the tee-mounted (socket) version for smaller pipe sizes or the adjustable pipe-thread mounted versions for use in pipes from 2 to 100".
Note: Hot-tap sensors do not include ball valve. Tee-mount sensors require GLI mounting hardware listed below
- Measuring range: 1 to 30 ft/sec
- Accuracy: ±1% of full scale from 1 to 30 ft/sec
- Repeatability: plus or minus 0.5% of full scale
- Linearity: plus or minus 1% of full scale
- Max pressure: 100 psi @ 77°F
- Max temp: 140°F @ 40 psi
- Mounting hardware: Sch 80 PVC
- Sensor cable: 20-ft, 2-conductor plus shield, extend to 2,000 ft
- Construction: polypropylene body & impeller, zirconia ceramic shaft
- Sensor type: tee mount