Product Details
  • Universal inputs accept your choice of up to four Hach flow and water quality sensors
  • Rugged IP66/NEMA 4X construction allows for permanent mounting indoors and out
  • Trigger external autosamplers during flow events

FL1500 flowmeters offer both control and data logging capabilities for a complete and powerful monitoring solution. Use them in permanent installations where you need accurate and reliable flow data—great throughout your plant and collection systems. They're suitable for installation indoors and outdoors (with optional sun/rain shield, stock # 69916).

Meters feature terminal block wiring connections for direct connection of Hach flow and water quality sensors, including FLO-DAR Flow Sensors, SubAV Flow Sensors, Ultrasonic Down-Looking and In-Pipe Flow Sensors, and BL9000 Bubbler Level Sensors. Meters require a field-installable AV9000S interface module (stock # 69907) when connecting a Hach SubAV sensor.

FL1500 meters can accommodate other peripheral equipment, such as tipping rain gauges and digital pH sensors. Advanced models also support external autosamplers (Hach AS950 and third-party models) and external totalizers. A robust selection of analog and digital outputs are included, but if you want to expand your meter's capabilities, the IO9004 extension I/O module (stock # 69911) adds three analog outputs, two analog/pulse inputs, four digital outputs and four relay outputs—all in a compact NEMA 4X housing.

Meters log and store over 829,000 data points at user-defined intervals for your selected sensor data and system events, such as alarms. You can set alarms to trigger a sampler to operate or change to a secondary logging interval if you need more frequent and precise data points during critical events. Up to 32 alarm types are available, including measurements (high/high, high, low, low/low, rate of change), system (low power, sensor timeout/error) and actions (log, trigger sampler, change logging interval).

Meters offer three different programming methods: enter information using the integral keypad; import a copied program from another meter using a USB memory stick; or program the meter with your PC using Hach's FSDATA® Desktop Software (available for free download at hach.com/flow). You can define sensor type, calibration setup information, data logging intervals, sensor naming and control output configuration. Physical installation is simple with the included flat surface mounting brackets, or purchase the optional pipe mount kit (stock # 69915).

Includes: mounting brackets and communications cable. For a complete system, order a flow meter, appropriate Hach sensors (purchase sensors separately)and accessories as required for your application.

Tech Specs:
  • Inputs: 4 sensors, 1 rain gauge, 1 analog input, 2 digital inputs
  • Alarms: up to 32 types for measurements, system and actions
  • Communication: direct PC USB B port, memory stick USB A port and RS485 MODBUS
  • Outputs: Relays: two SPDT, 2A; Analog: three 4-20mA; Auxiliary: AS950 sampler, IO9004 port, two digital
  • Supply voltage: 100 to 240 VAC, 50/60 Hz; 12 VDC lead acid backup battery port (battery sold separately)

Product Information

Item number
69904
Brand Name
Hach Company
Catalog Page
435
Net weight
10.4
Condition
New

FL1500 Hach Advanced Flowmeter, 4 Sensor Ports, 120 VAC, LFV001.99.W4NXH

Item number
69904
Brand Name
Hach Company
Catalog Page
435
Net weight
10.4
Condition
New
Price $6604.8
price per each
excl. tax
In Stock
each
Need Help? Call 800-548-1234
Product Details
  • Universal inputs accept your choice of up to four Hach flow and water quality sensors
  • Rugged IP66/NEMA 4X construction allows for permanent mounting indoors and out
  • Trigger external autosamplers during flow events

FL1500 flowmeters offer both control and data logging capabilities for a complete and powerful monitoring solution. Use them in permanent installations where you need accurate and reliable flow data—great throughout your plant and collection systems. They're suitable for installation indoors and outdoors (with optional sun/rain shield, stock # 69916).

Meters feature terminal block wiring connections for direct connection of Hach flow and water quality sensors, including FLO-DAR Flow Sensors, SubAV Flow Sensors, Ultrasonic Down-Looking and In-Pipe Flow Sensors, and BL9000 Bubbler Level Sensors. Meters require a field-installable AV9000S interface module (stock # 69907) when connecting a Hach SubAV sensor.

FL1500 meters can accommodate other peripheral equipment, such as tipping rain gauges and digital pH sensors. Advanced models also support external autosamplers (Hach AS950 and third-party models) and external totalizers. A robust selection of analog and digital outputs are included, but if you want to expand your meter's capabilities, the IO9004 extension I/O module (stock # 69911) adds three analog outputs, two analog/pulse inputs, four digital outputs and four relay outputs—all in a compact NEMA 4X housing.

Meters log and store over 829,000 data points at user-defined intervals for your selected sensor data and system events, such as alarms. You can set alarms to trigger a sampler to operate or change to a secondary logging interval if you need more frequent and precise data points during critical events. Up to 32 alarm types are available, including measurements (high/high, high, low, low/low, rate of change), system (low power, sensor timeout/error) and actions (log, trigger sampler, change logging interval).

Meters offer three different programming methods: enter information using the integral keypad; import a copied program from another meter using a USB memory stick; or program the meter with your PC using Hach's FSDATA® Desktop Software (available for free download at hach.com/flow). You can define sensor type, calibration setup information, data logging intervals, sensor naming and control output configuration. Physical installation is simple with the included flat surface mounting brackets, or purchase the optional pipe mount kit (stock # 69915).

Includes: mounting brackets and communications cable. For a complete system, order a flow meter, appropriate Hach sensors (purchase sensors separately)and accessories as required for your application.

Tech Specs:
  • Inputs: 4 sensors, 1 rain gauge, 1 analog input, 2 digital inputs
  • Alarms: up to 32 types for measurements, system and actions
  • Communication: direct PC USB B port, memory stick USB A port and RS485 MODBUS
  • Outputs: Relays: two SPDT, 2A; Analog: three 4-20mA; Auxiliary: AS950 sampler, IO9004 port, two digital
  • Supply voltage: 100 to 240 VAC, 50/60 Hz; 12 VDC lead acid backup battery port (battery sold separately)